Tecfluid XT5 Manuel d'utilisateur Page 8

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 24
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 7
2.3 Pulse output connection
Terminal
E Emitter.
C Collector.
8
2.4 Connection examples
The two usual ways to connect the alarm outputs are NPN or PNP modes, depending on if
the load is connected to the positive or negative terminal.
In the following figures, an example of connection for the alarm 2 in NPN and PNP mode can
be seen.
The pulse output is opto-isolated. The terminals are the collector and emitter of an NPN
bipolar transistor. Optionally this output can be supplied for AC loads (see 9.3).
In the case of using inductive loads, in order to protect the output transistor, the use of
free wheeling diodes is required.
E
Co i l
XT5
C
Vue de la page 7