5.8.4 Lining material
If the pipe has an internal lining, in this screen the lining material can be selected. In the
same way as in paragraph 5.8.2, if the material is not in the list, “Another material” must be
selected and the sound propagation velocity of the material must be entered.
In the event that the pipe does not have any internal lining, select “None”.
5.8.2 Pipe material
For the programming of the CU100 ultrasonic flowmeter, a list with several common pipe
materials is available. For each material the flowmeter has the necessary data to perform a
good measurement.
In the event that the pipe material is not on the list, you must select “Another material”, in the
last position in the list. In this case, the sound propagation velocity of the material must be
entered.
5.8.3 Pipe thickness
It is usually indicated on the pipe.